Specs at a glance
-
Laser wavelength
532 nm
-
Hazardous area certifications
ATEX, CSA, IECEx, UKCA, JPEx
Field of application
The Raman Rxn-30 probe has cross-industry appeal for its robust gas-phase headspace monitoring, in situ measurements, and material compatibility. Certified for use in hazardous area environments, the Raman Rxn-30 probe can be inserted directly into processes with temperatures up to 150 degrees Celsius and pressures up to 68.9 barg (1,000 psig). It is available with a variety of mounting options for maximum installation and sampling flexibility.
Chemical: ammonia, methanol, HyCO, reaction monitoring, blending, catalysis
Polymer: polymerization reaction monitoring
Gas-phase streams in refining: hydrogen production and recycle fuel blending, fuel characterization
Power & Energy: IGCC power plants, gas turbines
Pharmaceutical: API reaction monitoring, drying
Food & Beverage: fermentations, offgas, volatiles
Benefits
Reliable, quantitative gas-phase measurements
In situ measurement/no transfer lines or fast loops required
Can be directly inserted into processes with temperatures up to 150 °C and 68.9 barg (1,000 psig)
Industry standard installation options
Direct insertion, side insertion, or sample loop
Suitable for hazardous area/classified environments
Extended selection
-
High-end products
- Highly functional and convenient
Technical excellence
Simplicity
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
| FLEX selections | Technical excellence | Simplicity |
|---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
-
-
Technical Information (TI)
Rxn-30 Raman Spectroscopic Probe Technical Information
System design and specifications for the Raman Rxn-30 probe
EN 01/07/202214/09/2021Language:
English
Version:
01/07/2022
File size:
569.9 KB
File name:
TI01632CEN_0222.pdf
-
-
-
Operating Instruction (BA)
Rxn-30 ラマン分光プローブ 取扱説明書
Raman Rxn‑30 プローブの設定、操作、メンテナンスの詳細
EN 17/11/2025Language:
Japanese
Version:
17/11/2025
File size:
1.4 MB
File name:
BA02168CJA_0425.pdf
-
-
-
PU (Publication)
Raman spectroscopy for parahydrogen quantification - Real-time control and quality assurance across the hydrogen supply chain
This paper presents experimental findings that validate the performance
of an Endress+Hauser Raman spectroscopic analyzer in accurately
measuring parahydrogen conversion during the hydrogen liquefaction
process.Language:
English
Version:
13/01/2026
File size:
410.6 KB
File name:
PU01623CEN_0126.pdf
-
-
-
PU (Publication)
Raman Rxn5 アナライザレーザーベースの組成分析
Raman Rxn5アナライザ(Raman Rxn-30プローブ、Rxn-40プローブ、
Rxn-41プローブを含む)は、Kaiser Ramanテクノロジーを搭載した
、気相測定用のラマン分光計システムです。この概要パンフレット
では、これらの機器の特長と用途についてご紹介しています。Language:
Japanese
Version:
07/01/2026
File size:
955.5 KB
File name:
PU01444CJA_0225_Raman Rxn5 analyzer.pdf
-
-
-
PU (Publication)
Raman Rxn-30 probe - Gas phase analysis
An overview brochure about the Raman Rxn-30 probe, a
Raman spectroscopy probe for gas phase measurement
powered by Kaiser Raman technology in the Oil & Gas
industry and Chemical industry.Language:
English
Version:
20/01/2022
File size:
489.6 KB
File name:
PU01452CEN_0122.pdf
-
-
-
PU (Publication)
Raman Rxn-30 気相プローブ
この概要パンフレットでは、Kaiser Ramanテクノロジーを搭載した
ラマン分光法プローブ「Raman Rxn-30」について紹介しています。
Raman Rxn-30は、石油・ガス産業および化学産業における気相測定
に特化したプローブです。Language:
Japanese
Version:
12/12/2025
File size:
913 KB
File name:
PU01452CJA_0122_Raman Rxn-30.pdf
-
-
-
Innovation (IN)
Raman technology for the chemical industry - Reliable composition measurement of chemical process streams
An overview brochure about our Raman spectroscopy analyzer systems,
powered by Kaiser Raman technology, for the chemical industry
(includes the Raman Rxn2 analyzer, Raman Rxn4 analyzer,
Raman Rxn5 analyzer, and the Raman Rxn-10 probe, Raman Rxn-20 probe,
Raman Rxn-30 probe, Raman Rxn-40 probe, and Raman Rxn-41 probe).Language:
English
Version:
18/10/2021
File size:
10.6 MB
File name:
IN01223CEN_0121.pdf
-
-
-
Innovation (IN)
Raman-Sonden - Zuverlässige optische Analyse der chemischen Zusammensetzung
Eine Übersichtsbroschüre über unser Raman-Spektroskopie-Sondenportfolio
einschließlich der Sonden Rxn-10, Rxn-20, Rxn-30,
Rxn-40, Rxn-41, Rxn-45, Rxn-46 und Sonden-Zubehöroptiken
(bIO-Optic, Raman-Singel-Use optiken/SUB,
Immersionsoptik, berührungslose Optik),
die auf der Kaiser Raman-Technologie basiert.Language:
German
Version:
24/09/2025
File size:
1.1 MB
File name:
IN01225CDE_0121_Raman_Sonden_web.pdf
-
-
-
Innovation (IN)
Raman-Technologie in der chemischen Industrie
Zuverlässige Messung der Zusammensetzung
chemischer Prozessströme.Language:
German
Version:
28/07/2025
File size:
5.6 MB
File name:
IN01223C_11DE_0121_Raman_Chemie_web.pdf
-
-
-
White paper (WP)
Optimizing green ammonia production with Raman spectroscopy
A white paper about the use of Raman spectroscopy in green ammonia
production to ensure quality control and process efficiency, such
as with Raman systems that include a Raman Rxn5 analyzer and a
Rxn-30 probe.Language:
English
Version:
27/10/2025
File size:
577.2 KB
File name:
WP01275CEN_0125.pdf
-