  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Separated version with field housing and control room instrumentation

  • Supply / Communication

    4-wire (HART, Profibus DP, RS 485)

  • Ambient temperature

    -40 °C ... 80 °C

  • Process temperature

    -40 °C ... 150 °C

  • Process pressure absolute / max. overpressure limit

    0.7 bar ... 3 bar abs

  • Main wetted parts

    UP / AL-PTFE

  • Process connection

    G / NPT 1"

  • Blocking distance

    1,6 m

  • Max. measurement distance

    70 m

  • Certificates / Approvals

    ATEX
    FM
    CSA

  • Components

    Transmitter
    FMU860 / FMU862

  • Successor

    FDU96

  • Application limits

    Take notice of range diagram