This product is no longer available.
Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.
Predecessor
-
Successor
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections Technical excellence Simplicity - F
- L
- E
- X
Fundamental selection
Meet your basic measurement needs
Technical excellence Simplicity - F
- L
- E
- X
Lean selection
Handle your core processes easily
Technical excellence Simplicity - F
- L
- E
- X
Extended selection
Optimize your processes with innovative technologies
Technical excellence Simplicity - F
- L
- E
- X
Xpert selection
Master your most challenging applications
Technical excellence Simplicity Variable
-
-
Product headline
std_productprofile_product_usp_8119_1511861002.
std_productprofile_product_usp2_38907_1511797452.
For all basic applications and for 1-to-1 replacement of orifice plates. -
Sensor features
Easy alignment of the sensor – included centering rings. High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer. std_productprofile_product_benefits_8115.
Face-to-face length of 65 mm (2.56 in). No flanges. Low weight. -
Transmitter features
Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area). -
Nominal diameter range
DN 15 to 150 (½ to 6")
-
Wetted materials
Measuring tube: 1.4408 (C3FM)
DSC sensor: 1.4435 (316/316L) -
Measured variables
Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature
-
Max. measurement error
Volume flow (liquid): ±0.75 %
Volume flow (steam, gas): ±1.00 %
Mass flow (liquid): ±0.85%
Mass flow (steam, gas): ±1.7 % -
Measuring range
Liquid: 0.16 to 625 m³/h (0.09 to 368 ft³/min)
depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
Steam, gas: 2 to 8342 m³/h (1.18 to 4910 ft³/min)
depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a) -
Max. process pressure
PN 40, Class 300, 20K
-
Medium temperature range
Standard: –40 to +260 °C (–40 to +500 °F)
High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
High/low temperature (on request): –200 to +450 °C (–328 to +842 °F) -
Ambient temperature range
Compact version (standard): –40 to +80 °C (–40 to +176 °F)
Compact version (option): –50 to +80 °C (–58 to +176 °F)
Remote version (standard): –40 to +85 °C (–40 to +185 °F)
Remote version (option): –50 to +85 °C (–58 to +185 °F) -
Sensor housing material
Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)
-
Transmitter housing material
AlSi10Mg, coated; 1.4404 (316L)
-
Degree of protection
Compact version: IP66/67, type 4X enclosure
Sensor remote version: IP66/67, type 4X enclosure
Transmitter remote version: IP66/67, type 4X enclosure -
Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available -
Outputs
4‐20 mA HART (passive)
4‐20 mA (passive)
Pulse/frequency/switch output (passive) -
Inputs
Current input 4‐20 mA (passive)
-
Digital communication
HART, PROFIBUS PA, FOUNDATION Fieldbus
-
Power supply
DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output) -
Hazardous area approvals
ATEX, IECEx, cCSAus, EAC
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) -
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
NACE MR0175/MR0103, PMI (on request)
-
Product headline
std_productprofile_product_usp_8119_1511861002.
std_productprofile_product_usp2_38907_1511797452.
For all basic applications and for 1-to-1 replacement of orifice plates. -
Sensor features
Easy alignment of the sensor – included centering rings. High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer. std_productprofile_product_benefits_8115.
Face-to-face length of 65 mm (2.56 in). No flanges. Low weight. -
Transmitter features
Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area). -
Nominal diameter range
DN 15 to 150 (½ to 6")
-
Wetted materials
Measuring tube: 1.4408 (C3FM)
DSC sensor: 1.4435 (316/316L) -
Measured variables
Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature
-
Max. measurement error
Volume flow (liquid): ±0.75 %
Volume flow (steam, gas): ±1.00 %
Mass flow (liquid): ±0.85%
Mass flow (steam, gas): ±1.7 % -
Measuring range
Liquid: 0.16 to 625 m³/h (0.09 to 368 ft³/min)
depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
Steam, gas: 2 to 8342 m³/h (1.18 to 4910 ft³/min)
depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a) -
Max. process pressure
PN 40, Class 300, 20K
-
Medium temperature range
Standard: –40 to +260 °C (–40 to +500 °F)
High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
High/low temperature (on request): –200 to +450 °C (–328 to +842 °F) -
Ambient temperature range
Compact version (standard): –40 to +80 °C (–40 to +176 °F)
Compact version (option): –50 to +80 °C (–58 to +176 °F)
Remote version (standard): –40 to +85 °C (–40 to +185 °F)
Remote version (option): –50 to +85 °C (–58 to +185 °F) -
Sensor housing material
Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)
-
Transmitter housing material
AlSi10Mg, coated; 1.4404 (316L)
-
Degree of protection
Compact version: IP66/67, type 4X enclosure
Sensor remote version: IP66/67, type 4X enclosure
Transmitter remote version: IP66/67, type 4X enclosure -
Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available -
Outputs
4‐20 mA HART (passive)
4‐20 mA (passive)
Pulse/frequency/switch output (passive) -
Inputs
4‐20 mA (passive)
-
Digital communication
HART, PROFIBUS PA, FOUNDATION Fieldbus
-
Power supply
DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output) -
Hazardous area approvals
ATEX, IECEx, cCSAus
-
Other approvals and certificates
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
-
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
NACE MR0175/MR0103, PMI (on request)
-
Product headline
std_productprofile_product_usp_8119_1511861002.
std_productprofile_product_usp2_38907_1511797452.
For all basic applications and for 1-to-1 replacement of orifice plates. -
Sensor features
Easy alignment of the sensor – included centering rings. High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer. std_productprofile_product_benefits_8115.
Face-to-face length of 65 mm (2.56 in). No flanges. Low weight. -
Transmitter features
Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area). -
Nominal diameter range
DN 15 to 150 (½ to 6")
-
Wetted materials
Measuring tube: 1.4408 (C3FM)
DSC sensor: 1.4435 (316/316L) -
Measured variables
Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature
-
Max. measurement error
Volume flow (liquid): ±0.75 %
Volume flow (steam,, gas): ±1.00 %
Mass flow (liquid): ±0.85%
Mass flow (steam,, gas): ±1.7 % -
Measuring range
Liquid: 0.16 to 625 m³/h (0.09 to 368 ft³/min)
depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
Steam, gas: 2 to 8342 m³/h (1.18 to 4910 ft³/min)
depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a) -
Max. process pressure
PN 40, Class 300, 20K
-
Medium temperature range
Standard: –40 to +260 °C (–40 to +500 °F)
High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
High/low temperature (on request): –200 to +450 °C (–328 to +842 °F) -
Ambient temperature range
Compact version (standard): –40 to +80 °C (–40 to +176 °F)
Compact version (option): –50 to +80 °C (–58 to +176 °F)
Remote version (standard): –40 to +85 °C (–40 to +185 °F)
Remote version (option): –50 to +85 °C (–58 to +185 °F) -
Sensor housing material
Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)
-
Transmitter housing material
AlSi10Mg, coated; 1.4404 (316L)
-
Degree of protection
Compact version: IP66/67, type 4X enclosure
Sensor remote version: IP66/67, type 4X enclosure
Transmitter remote version: IP66/67, type 4X enclosure -
Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available -
Outputs
4‐20 mA HART (passive)
4‐20 mA (passive)
Pulse/frequency/switch output (passive) -
Inputs
4‐20 mA (passive)
-
Digital communication
HART, PROFIBUS PA, FOUNDATION Fieldbus
-
Power supply
DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output) -
Hazardous area approvals
ATEX, IECEx, cCSAus, EAC
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC
17025) -
Pressure approvals and certificates
PED, CRN
-
Material certificates
NACE MR0175/MR0103, PMI (on request)
3.1 material
-
-
Installation Instructions (EA)
Replacing the transmitter Installation Instructions
-
Installation Instructions (EA)
English version - 12/2017New version available in EnglishProwirl 200
EN 01/12/2017Language:
English
Version:
01/12/2017
File size:
743.4 KB
File name:
EA01056DA2_0317.pdf
-
-
-
Special Documentation (SD)
SD IEC 61406
-
Special Documentation (SD)
English version - 02/2025New version available in EnglishAutomatic identification of physical objects
EN 07/02/202517/05/2024Language:
English
Version:
07/02/2025
File size:
649.2 KB
File name:
SD02825DEN_0525-00.pdf
-
-
-
SIL Declaration
Product family: Prowirl C, Prowirl D, Prowirl F, Prowirl L, Prowirl O, Prowirl R
-
SIL Declaration
English version - 07/2025New version available in EnglishProduct root: 7C2B-, 7D2B-, 7D2C-, 7F2B-, 7F2C-, 7L2D-, 7O2B-, 7O2C-, 7R2B-, 7R2C-
Declaration number: SIL_00555_01.25
Safety function: Flow monitoring
Protection: MAX, RANGE
Safety-related output signal: 4...20 mA
Systematic safety integrity: SIL 3
Hardware safety integrity: SIL 2EN 21/07/2025Language:
English
Version:
21/07/2025
File size:
738.1 KB
File name:
SIL_00555_01.25.pdf
-
-
-
Metrology
Product family: Prowirl D, Prowirl F, Prowirl O, Prowirl R
-
Metrology
12/2019New version available in EnglishProduct root: 7D2B-, 7D2C-, 7F2B-, 7F2C-, 7O2B-, 7O2C-, 7R2B-, 7R2C-
Region: Ukrain
Approval agency: SE Ukrmetrteststandard
Approval number: UA.TR.001 297-19
Metrology type: MetrologyLanguage:
Unknown
Version:
26/12/2019
File size:
248.8 KB
File name:
UA.TR.001-297-19_Prowirl200_ZE000.pdf
-
-
-
Device Type Manager (DTM)
Device Type Manager (DTM) - Prowirl 200 - HART
-
Device Type Manager (DTM)
Language neutral - 06/2025New version available in EnglishEndress+Hauser, DeviceCare, 1.08.08
Yokogawa, Plant Resource Manager, R3.12
Honeywell, Field Device Manager, R430.1
Endr
ess+Hauser, FieldCare, 2.19.00
Endress+Hauser, Field Xpert SMT70, 1.08.08Language:
Language neutral
Version:
27/06/2025
File size:
102.7 MB
File name:
EH_Prowirl_200_7x2B_HART_FW_1_02_zz_Dev_Rev_3.zip
-
-
-
Device Type Manager (DTM)
Device Type Manager (DTM) - Prowirl 200 - FOUNDATION Fieldbus H1
-
Device Type Manager (DTM)
Language neutral - 06/2025New version available in EnglishEndress+Hauser, DeviceCare, 1.08.08
Yokogawa, Plant Resource Manager, R3.12
Honeywell, Field Device Manager, R430.1
Endr
ess+Hauser, FieldCare, 2.19.00
Endress+Hauser, Field Xpert SMT70, 1.08.08Language:
Language neutral
Version:
27/06/2025
File size:
104.6 MB
File name:
EH_Prowirl_200_7x2B_FF_FW_1_00_zz_Dev_Rev_1.zip
-
-
-
Device Type Manager (DTM)
Device Type Manager (DTM) - Prowirl 200 - HART
-
Device Type Manager (DTM)
Language neutral - 06/2025New version available in EnglishEndress+Hauser, DeviceCare, 1.08.08
Honeywell, Field Device Manager, R430.1
Endress+Hauser, FieldCare, 2.19.00
Yokogawa,
Plant Resource Manager, R3.10
Endress+Hauser, Field Xpert SMT70, 1.08.08
Yokogawa, FieldMate, 2.05Language:
Language neutral
Version:
27/06/2025
File size:
109.4 MB
File name:
EH_Prowirl_200_7x2Bxx_HART_FW_1_00_zz_Dev_Rev_1.zip
-
-
-
Device Type Manager (DTM)
Device Type Manager (DTM) - Prowirl 200 - HART
-
Device Type Manager (DTM)
Language neutral - 06/2025New version available in EnglishEndress+Hauser, DeviceCare, 1.08.08
Honeywell, Field Device Manager, R450.1
Schneider Invensys, ArchestrA IDE, 4.0.04001<br/
>Yokogawa, Plant Resource Manager, R3.31
Endress+Hauser, FieldCare, 2.19.00
Endress+Hauser, Field Xpert SMT70, 1.08.08
P
ACTware, PACTware, 5.0Language:
Language neutral
Version:
06/06/2025
File size:
126.5 MB
File name:
EH_Prowirl_200_7x2B_7x2C_HART_FW_1_03_zz_Dev_Rev_04.zip
-
-
-
Device Type Manager (DTM)
Device Type Manager (DTM) - Prowirl 200 - PROFIBUS PA
-
Device Type Manager (DTM)
Language neutral - 05/2025New version available in EnglishEndress+Hauser, DeviceCare, 1.08.08
Endress+Hauser, FieldCare, 2.19.00
Endress+Hauser, Field Xpert SMT70, 1.08.08Language:
Language neutral
Version:
14/05/2025
File size:
100.9 MB
File name:
EH_Prowirl_200_7x2Bxx_PA_FW_1_00_zz_Dev_Rev_1.zip
-
-
-
Device Type Manager (DTM)
Device Type Manager (DTM) - Prowirl 200 - HART
-
Device Type Manager (DTM)
Language neutral - 06/2025New version available in EnglishEndress+Hauser, DeviceCare, 1.08.08
Endress+Hauser, FieldCare, 2.19.00
Endress+Hauser, Field Xpert SMT70, 1.08.08Language:
Language neutral
Version:
27/06/2025
File size:
110.2 MB
File name:
EH_Prowirl_200_7x2B_HART_FW_1_01_zz_Dev_Rev_2.zip
-