Specs at a glance
-
Accuracy
class B acc. to IEC 60751
class A acc. to IEC 60751
class AA acc. to IEC 60751 -
Response time
depending on configuration
iTHERM QuickSens: t90 = 1,5 s
iTHERM StrongSens: t90 = 9,5 s -
Max. process pressure (static)
at 20 °C: 40 bar (580 psi)
-
Operating temperature range
PT100 WW:
-200 °C … 600 °C
(-328 °F … 1.112 °F)
iTHERM StrongSens:
-50 °C … 500 °C
(-58 °F … 932 °F)
iTHERM QuickSens:
-50 °C … 200 °C
(-58 °F … 392 °F)
PT100 TF:
-50 °C … 200 °C
(-58 °F … 392 °F) -
Max. immersion length on request
48"
Field of application
It has been designed to meet the requirements of the Food & Beverages and Life Sciences industries and complies with the highest quality standards. It offers a variety of versions within a clearly segmented standard product. The result: Time and cost savings by simple and fast product selection. It offers many technical innovations: iTHERM QuickSens, StrongSens or QuickNeck. This leads to distinctive reduction of maintenance costs, improved product quality, process efficiency and safety.
Specially designed for use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industries
Measuring range: –200 to +600 °C (–28 to +1 112 °F)
Pressure range up to 40 bar (580 psi)
Protection class: up to IP69K
Benefits
-
User-friendly and reliable from product selection to maintenance
-
iTHERM inserts: globally unique, fully-automated production. Full traceability and consistently high product quality for reliable measured values
-
iTHERM QuickSens: fastest response times (t90s: 1.5 s) for optimum process control
-
iTHERM StrongSens: unsurpassed vibration resistance (> 60g) for ultimate plant safety
-
iTHERM QuickNeck – cost and time savings thanks to simple, tool-free recalibration
-
iTHERM TA30R: 316L terminal head for easier handling and lower installation and maintenance costs, and with highest IP69K rating
-
International certification: explosion protection e.g. ATEX/IECEx/FM/CSA and in compliance with hygiene standards according to 3-A, EHEDG, ASME BPE, FDA, TSE Certificate of Suitability
Extended selection
-
High-end products
- Highly functional and convenient
Technical excellence
Simplicity
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
| FLEX selections | Technical excellence | Simplicity |
|---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
imperial style
modular temperature assembly
hygienic/aseptic design (3-A®, EHEDG, ASME BPE, FDA)
hygienic process connections
with neck
suitable for hazardous areas
incl. protection tube
iTHERM QuickSens for fastest response time
iTHERM StrongSens for most robust design
iTHERM QuickNeck for easy and cost saving recalibration -
Thermowell / protection tube
without
incl. thermowell
incl. Tee-/elbow thermowell -
Insert / probe
mineral insulated (MI), flexible
pipe version, isolated wires, not flexible -
Outer diameter protection tube / Insert
1/4'' (6,35 mm)
3/8'' (9,53 mm)
1/2" (12,7 mm) -
Max. immersion length on request
48"
-
Material protection tube/ thermowell
316L
-
Process connection
Weld-in adapter
Tri-clamp
Clamp-connections according to ISO2852
G3/4" Liquiphant
G1" Liquiphant
Varivent
T- and elbow thermowell -
Tip shape
straight
reduced -
Surface roughness Ra
30 μin (0,76 μm)
15 μin (0,38 μm )
15 μin (0,38 μm) electropolished -
Operating temperature range
PT100 WW:
-200 °C … 600 °C
(-328 °F … 1.112 °F)
iTHERM StrongSens:
-50 °C … 500 °C
(-58 °F … 932 °F)
iTHERM QuickSens:
-50 °C … 200 °C
(-58 °F … 392 °F)
PT100 TF:
-50 °C … 200 °C
(-58 °F … 392 °F) -
Max. process pressure (static)
at 20 °C: 40 bar (580 psi)
-
Accuracy
class B acc. to IEC 60751
class A acc. to IEC 60751
class AA acc. to IEC 60751 -
Response time
depending on configuration
iTHERM QuickSens: t90 = 1,5 s
iTHERM StrongSens: t90 = 9,5 s -
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Ex - approvals
ATEX Ex nA
ATEX IECEx Ex ia, Ex tb
CSA C/US IS, NI
CSA NI
CSA IS, NI
FM NI
FM IS, NI
FM+CSA IS, NI -
Certification
SIL (transmitter only)
-
-
Technical Information (TI)
TI Weld-in adapter, process adapter and flanges
-
Technical Information (TI)
English version - 12/2024New version available in EnglishLevel, pressure and temperature measurement
EN 06/12/202425/03/202415/09/202328/10/202130/07/2021Language:
English
Version:
06/12/2024
File size:
1.3 MB
File name:
TI00426FEN_2624.pdf
-
-
-
Technical Information (TI)
TI iTHERM ModuLine TM412 Hygienic modular thermometer
-
Technical Information (TI)
English version - 08/2025New version available in EnglishImperial RTD thermometer with or without thermowell for hygienic applications
EN 31/08/2025Language:
English
Version:
31/08/2025
File size:
2.7 MB
File name:
TI01348TEN_0725-00.pdf
-
-
-
Operating Instruction (BA)
BA Modular hygienic thermometers
-
Operating Instruction (BA)
English version - 08/2025New version available in EnglishUniversal modular thermometers with RTD insert for hygienic applications
EN 31/08/2025Language:
English
Version:
31/08/2025
File size:
1 MB
File name:
BA02023TEN_0225-00.pdf
-
-
-
Installation Instructions (EA)
Bild TA20 AB
-
Installation Instructions (EA)
English version - 04/2025New version available in EnglishBild TA20 AB
EN 01/04/2025Language:
English
Version:
01/04/2025
File size:
109.8 KB
File name:
Bild TA20AB.pdf
-
-
-
Installation Instructions (EA)
Bild TA30D
-
Installation Instructions (EA)
English version - 08/2025New version available in EnglishBild TA30D
EN 18/08/2025Language:
English
Version:
18/08/2025
File size:
260.1 KB
File name:
Bild_TA30D.pdf
-
-
-
Installation Instructions (EA)
Bild TA30EB
-
Installation Instructions (EA)
English version - 08/2025New version available in EnglishBild TA30EB
EN 18/08/2025Language:
English
Version:
18/08/2025
File size:
181.8 KB
File name:
Bild TA30EB.pdf
-
-
-
Installation Instructions (EA)
Bild TA30A
-
Installation Instructions (EA)
English version - 08/2025New version available in EnglishBild TA30A
EN 18/08/2025Language:
English
Version:
18/08/2025
File size:
220.8 KB
File name:
Bild_TA30A.pdf
-
-
-
Installation Instructions (EA)
Typenschild DIENST-T
-
Installation Instructions (EA)
English version - 11/2025New version available in EnglishTypenschild DIENST-T
EN 03/11/2025Language:
English
Version:
03/11/2025
File size:
294.5 KB
File name:
DIENST_T.pdf
-
-
-
Ex Safety Instruction (XA)
XA TR1x, Tx88, TSx310, Tx6x, TC1x, TPx100, TM411, TR24
-
Ex Safety Instruction (XA)
English version - 08/2023New version available in EnglishThermometers and inserts
Ex ia IIC T1...T6 Ga
Ex ia IIIC T<sub>200</sub> 85 °C...T<sub>200
</sub> 450 °C DaEN 30/08/202315/05/2023Language:
English
Version:
30/08/2023
File size:
474.5 KB
File name:
XA02109TEN_0323-00.pdf
-
-
-
Ex Safety Instruction (XA)
TM411, TM412
-
Ex Safety Instruction (XA)
English version - 06/2018New version available in EnglishControl Drawing
FM IS, NIEN 15/06/201801/12/2014Language:
English
Version:
15/06/2018
File size:
79.3 KB
File name:
XA01150TEN_0218.pdf
-
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD drawings CAD drawings
- CAD drawings
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons
Individual configuration
Often bought together
Accessories